TAYLOR GLACIER EDDY CORRELATION STATION


1995/96 File Descriptions

Filename: rov95608.dat
Station: Roving eddy correlation station - met data
Location: Stake 83, Taylor Glacier
Date of Establishment: Dec 8, 1995 by Karen Lewis
Author of this report: Karen Lewis
File Period: Dec 18/95 (352) @ 13:15 to Dec 19/95 (353) @ 15:45
Sampling Frequency: every 2 seconds
Averaging and Output Interval: every 15 minutes
Program name: eddy version 1.2
 
 
* 1. array I.D.
     o1
2. day
     ok
3. time
     ok
4. mean W'
     ok
5. mean T'
     ok
6. mean lnVh'
     ok
7. mean Vh'
     ok
8. standard deviation W
     o1
9. standard deviation T
     o1
10. standard deviation lnVh
     o1
11. standard deviation Vh
     o1
12. sample H
     omit first two timesteps; remaining data ok
13. sample LE
     omit first two timesteps; remaining data ok
14. Sample
     omit first two timesteps; remaining data ok
 
*Notes:
1. Process only arrays with ID# 21
2. Array ID# 12 is EC data; array ID# 11 is startup information
including calibration coefficients used for instruments.

 
Filename: rov95609.dat
Station: Roving eddy correlation station - met data
Location: Stake 83, Taylor Glacier
Date of Establishment: Dec 8, 1995 by Karen Lewis
Author of this report: Karen Lewis
File Period: Dec 19/95 (353) @ 16:00 to Dec 20/95 (354) @ 14:45
Sampling Frequency: every 2 seconds
Averaging and Output Interval: every 15 minutes
Program name: eddy version 1.2
 
* 1. array I.D.
     o1
2. day
     ok
3. time
     ok
4. mean W'
     ok
5. mean T'
     ok
6. mean lnVh'
     ok
7. mean Vh'
     ok
8. standard deviation W
     o1
9. standard deviation T
     o1
10. standard deviation lnVh
     o1
11. standard deviation Vh
     o1
12. sample H
     omit first two and last timesteps; remaining data ok
13. sample LE
     omit first two and last timesteps; remaining data ok
14. Sample
     omit first two and last timesteps; remaining data ok
 
*Notes:
1. Process only arrays with ID# 21
2. Array ID# 12 is EC data; array ID# 11 is startup information
including calibration coefficients used for instruments.