Filename: caa94501.dat
Station: Canada Glacier met station
Date of Establishment: Dec 1, 1994 by Gayle Dana
Author of this report: Karen Lewis
File Period: Dec 1/94 (335) @ 15:40 to Dec 3/94 (337) @ 12:40
Sampling Frequency: every 1 seconds
Averaging and Output Interval: every 20 minutes
Program name: canec2
 
1. array I.D.
     o1
2. day
     ok
3. time
     ok
4. mean horizontal wind speed (m/s)
     ok
5. resultant mean wind direction (degrees from north)
     ok
6. mean rh @ 2 meters (%/100)
     some bad; multiply good values by 100 to standardize with
      LTER measurements
7. mean air temp. @ 2 meters (C)
     convert to mV, then clow
8. mean vapor pressure (kPa)
     some bad
9. mean barometric pressure (mbar)
     ok
10. mean surface temperature (C)
     bad
11. mean solar flux coming down (W/m2)
     ok
12. mean solar flux going up (W/m2)
     ok
13. mean soil temperature (TCAV)
     bad
14. mean net radiation (W/m2)
     ok
15. mean soil heat flux (W/m2)
     bad
* 16. mean sensible heat flux (W/m2)
     bad for last timestep; remaining ok
17. mean latent heat flux (W/m2)
     bad for last timestep; remaining ok
18. mean vertical wind speed (W)
     bad for last timestep; remaining ok
19. mean vertical temperature flux (T)
     bad for last timestep; remaining ok
20. mean vertical vapor flux (Vk)
     bad for last timestep; remaining ok
21. variance (W)
     bad for last timestep; remaining ok
22. variance (T)
     bad for last timestep; remaining ok
23. variance (Vk)
     bad for last timestep; remaining ok
24. covariance W-T
     bad for last timestep; remaining ok
25. covariance W-Vk
     bad for last timestep; remaining ok
26. evaporation rate (mm/20min)
     bad for last timestep; remaining ok
27. sample battery voltage
     o1
 
*Notes:
1. this station and program both belong to Scott Tyler at DRI so
they are slightly different than the LTER standard.
2. Eddy correlation data available - process 16 on.
 

Filename: caa94504.dat
Station: Canada Glacier met station
Date of Establishment: Dec 1, 1994 by Gayle Dana
Author of this report: Karen Lewis
File Period: Dec 12/94 (346) @ 12:40 to Dec 13/94 (347) @ 21:00
Sampling Frequency: every 1 seconds
Averaging and Output Interval: every 20 minutes
Program name: canec2
 
1. array I.D.
     o1
2. day
     ok
3. time
     ok
4. mean horizontal wind speed (m/s)
     ok
5. resultant mean wind direction (degrees from north)
     ok
6. mean rh @ 2 meters (%/100)
     multiply by 100 to standardize with LTER measurements
7. mean air temp. @ 2 meters (C)
     convert to mV, then clow
8. mean vapor pressure (kPa)
     ok
9. mean barometric pressure (mbar)
     ok
10. mean surface temperature (C)
     bad
11. mean solar flux coming down (W/m2)
     ok
12. mean solar flux going up (W/m2)
     ok
13. mean soil temperature (TCAV)
     bad
14. mean net radiation (W/m2)
     ok
15. mean soil heat flux (W/m2)
     bad
* 16. mean sensible heat flux (W/m2)
     bad for first and last timestep; remaining ok
17. mean latent heat flux (W/m2)
     bad for first and last timestep; remaining ok
18. mean vertical wind speed (W)
     bad for first and last timestep; remaining ok
19. mean vertical temperature flux (T)
     bad for first and last timestep; remaining ok
20. mean vertical vapor flux (Vk)
     bad for first and last timestep; remaining ok
21. variance (W)
     bad for first and last timestep; remaining ok
22. variance (T)
     bad for first and last timestep; remaining ok
23. variance (Vk)
     bad for first and last timestep; remaining ok
24. covariance W-T
     bad for first and last timestep; remaining ok
25. covariance W-Vk
     bad for first and last timestep; remaining ok
26. evaporation rate (mm/20min)
     bad for first and last timestep; remaining ok
27. sample battery voltage
     o1
 
*Notes:
1. This station and program both belong to Scott Tyler at DRI so
they are slightly different than the LTER standard.
2. Eddy correlation data available - process 16 on.
 

Filename: caa94506.dat
Station: Canada Glacier met station
Date of Establishment: Dec 1, 1994 by Gayle Dana
Author of this report: Karen Lewis
File Period: Dec 19/94 (353) @ 15:20 to Dec 21/94 (355) @ 17:20
Sampling Frequency: every 1 seconds
Averaging and Output Interval: every 20 minutes
Program name: canec2
(Note: this station and program both belong to Scott Tyler at DRI so
they are slightly different than the LTER standard)
 
1. array I.D.
     o1
2. day
     ok
3. time
     ok
4. mean horizontal wind speed (m/s)
     ok
5. resultant mean wind direction (degrees from north)
     ok
6. mean rh @ 2 meters (%/100)
     multiply by 100 to standardize with LTER measurements
7. mean air temp. @ 2 meters (C)
     convert to mV, then clow
8. mean vapor pressure (kPa)
     ok
9. mean barometric pressure (mbar)
     ok
10. mean surface temperature (C)
     bad
11. mean solar flux coming down (W/m2)
     ok
12. mean solar flux going up (W/m2)
     ok
13. mean soil temperature (TCAV)
     bad
14. mean net radiation (W/m2)
     ok
15. mean soil heat flux (W/m2)
     bad
* 16. mean sensible heat flux (W/m2)
     bad for first and last timesteps; remaining ok
17. mean latent heat flux (W/m2)
     bad for first and last timesteps; remaining ok
18. mean vertical wind speed (W)
     bad for first and last timesteps; remaining ok
19. mean vertical temperature flux (T)
     bad for first and last timesteps; remaining ok
20. mean vertical vapor flux (Vk)
     bad for first and last timesteps; remaining ok
21. variance (W)
     bad for first and last timesteps; remaining ok
22. variance (T)
     bad for first and last timesteps; remaining ok
23. variance (Vk)
     bad for first and last timesteps; remaining ok
24. covariance W-T
     bad for first and last timesteps; remaining ok
25. covariance W-Vk
     bad for first and last timesteps; remaining ok
26. evaporation rate (mm/20min)
     bad for first and last timesteps; remaining ok
27. sample battery voltage
     o1
 
*Notes:
1. This station and program both belong to Scott Tyler at DRI so
they are slightly different than the LTER standard.
2. Eddy correlation data available - process 16 on.
 

Filename: caa94508.dat
Station: Canada Glacier met station
Date of Establishment: Dec 1, 1994 by Gayle Dana
Author of this report: Karen Lewis
File Period: Jan 1/95 (1) @ 14:40 to Jan 3/95 (3) @ 9:00
Sampling Frequency: every 1 seconds
Averaging and Output Interval: every 20 minutes
Program name: canec2
 
1. array I.D.
     o1
2. day
     ok
3. time
     ok
4. mean horizontal wind speed (m/s)
     ok
5. resultant mean wind direction (degrees from north)
     ok
6. mean rh @ 2 meters (%/100)
     multiply by 100 to standardize with LTER measurements
7. mean air temp. @ 2 meters (C)
     convert to mV, then clow
8. mean vapor pressure (kPa)
     ok
9. mean barometric pressure (mbar)
     ok
10. mean surface temperature (C)
     ok
11. mean solar flux coming down (W/m2)
     ok
12. mean solar flux going up (W/m2)
     ok
13. mean soil temperature (TCAV)
     bad
14. mean net radiation (W/m2)
     ok
15. mean soil heat flux (W/m2)
     bad
16. mean sensible heat flux (W/m2)
     bad for first and last timesteps; remaining ok
17. mean latent heat flux (W/m2)
     bad for first and last timesteps; remaining ok
18. mean vertical wind speed (W)
     bad for first and last timesteps; remaining ok
19. mean vertical temperature flux (T)
     bad for first and last timesteps; remaining ok
20. mean vertical vapor flux (Vk)
     bad for first and last timesteps; remaining ok
21. variance (W)
     bad for first and last timesteps; remaining ok
22. variance (T)
     bad for first and last timesteps; remaining ok
23. variance (Vk)
     bad for first and last timesteps; remaining ok
24. covariance W-T
     bad for first and last timesteps; remaining ok
25. covariance W-Vk
     bad for first and last timesteps; remaining ok
26. evaporation rate (mm/20min)
     bad for first and last timesteps; remaining ok
27. sample battery voltage
     o1
 
*Notes:
1. This station and program both belong to Scott Tyler at DRI so
they are slightly different than the LTER standard.
2. Eddy correlation data available - process 16 on.
 

Filename: caa94510.dat
Station: Canada Glacier met station
Date of Establishment: Dec 1, 1994 by Gayle Dana
Author of this report: Karen Lewis
File Period: Jan 7/95 (7) @ 13:40 to Jan 11/95 (11) @ 17:20
Sampling Frequency: every 1 seconds
Averaging and Output Interval: every 20 minutes
Program name: canec2
 
1. array I.D.
     o1
2. day
     ok
3. time
     ok
4. mean horizontal wind speed (m/s)
     ok
5. resultant mean wind direction (degrees from north)
     ok
6. mean rh @ 2 meters (%/100)
     multiply by 100 to standardize with LTER measurements
7. mean air temp. @ 2 meters (C)
     convert to mV, then clow
8. mean vapor pressure (kPa)
     ok
9. mean barometric pressure (mbar)
     ok
10. mean surface temperature (C)
     ok
11. mean solar flux coming down (W/m2)
     ok
12. mean solar flux going up (W/m2)
     ok
13. mean soil temperature (TCAV)
     bad
14. mean net radiation (W/m2)
     ok
15. mean soil heat flux (W/m2)
     bad
* 16. mean sensible heat flux (W/m2)
     bad for first timestep; remaining ok
17. mean latent heat flux (W/m2)
     bad for first timestep; remaining ok
18. mean vertical wind speed (W)
     bad for first timestep; remaining ok
19. mean vertical temperature flux (T)
     bad for first timestep; remaining ok
20. mean vertical vapor flux (Vk)
     bad for first timestep; remaining ok
21. variance (W)
     bad for first timestep; remaining ok
22. variance (T)
     bad for first timestep; remaining ok
23. variance (Vk)
     bad for first timestep; remaining ok
24. covariance W-T
     bad for first timestep; remaining ok
25. covariance W-Vk
     bad for first timestep; remaining ok
26. evaporation rate (mm/20min)
     bad for first timestep; remaining ok
27. sample battery voltage
     o1
 
*Notes:
1. This station and program both belong to Scott Tyler at DRI so
they are slightly different than the LTER standard.
2. Eddy correlation data available - process 16 on.
 

1995/96 File Descriptions

 
Filename: rov95601.dat
Station: Roving eddy correlation station - ec data
Location: Stake 50, Canada Glacier
Date of Establishment: Dec 8, 1995 by Karen Lewis
Author of this report: Karen Lewis
File Period: Dec 8/95 (342) @ 14:15 to Dec 11/95 (345) @ 12:15
Sampling Frequency: every 2 seconds
Averaging and Output Interval: every 15 minutes
Program name: eddy version 1.2
 
*Notes:
1. Process only arrays with ID# 12
2. Array ID# 21 is met data; array ID# 11 is startup information
including calibration coefficients used for instruments.
3. NO EDDY CORRELATION DATA WAS RECORDED FOR rov95601.dat
 

Filename: rov95602.dat
Station: Roving eddy correlation station - met data
Location: Stake 53, Canada Glacier
Date of Establishment: Dec 8, 1995 by Karen Lewis
Author of this report: Karen Lewis
File Period: Dec 11/95 (345) @ 15:45 to Dec 12/95 (346) @ 11:00
Sampling Frequency: every 2 seconds
Averaging and Output Interval: every 15 minutes
Program name: eddy version 1.2
 
*Notes:
1. Process only arrays with ID# 21
2. Array ID# 12 is EC data; array ID# 11 is startup information
including calibration coefficients used for instruments.
3. NO EDDY CORRELATION DATA WAS RECORDED FOR rov95602.dat
 

Filename: rov95603.dat
Station: Roving eddy correlation station - met data
Location: Stake 53, Canada Glacier
Date of Establishment: Dec 8, 1995 by Karen Lewis
Author of this report: Karen Lewis
File Period: Dec 12/95 (346) @ 11:15 to Dec 12/95 (346) @ 19:30
Sampling Frequency: every 2 seconds
Averaging and Output Interval: every 15 minutes
Program name: eddy version 1.2
 
* 1. array I.D.
     o1
2. day
     ok
3. time
     ok
4. mean W'
     ok
5. mean T'
     ok
6. mean lnVh'
     ok
7. mean Vh'
     ok
8. standard deviation W
     o1
9. standard deviation T
     o1
10. standard deviation lnVh
     o1
11. standard deviation Vh
     o1
12. sample H
     omit first timestep; remaining data ok
13. sample LE
     omit first timestep; remaining data ok
14. Sample
     omit first timestep; remaining data ok
 
*Notes:
1. Process only arrays with ID# 21
2. Array ID# 12 is EC data; array ID# 11 is startup information
including calibration coefficients used for instruments.
 

Filename: rov95604.dat
Station: Roving eddy correlation station - met data
Location: Stake 53, Canada Glacier
Date of Establishment: Dec 8, 1995 by Karen Lewis
Author of this report: Karen Lewis
File Period: Dec 12/95 (346) @ 19:45 to Dec 13/95 (347) @ 20:15
Sampling Frequency: every 2 seconds
Averaging and Output Interval: every 15 minutes
Program name: eddy version 1.2
 
*Notes:
1. Process only arrays with ID# 21
2. Array ID# 12 is EC data; array ID# 11 is startup information
including calibration coefficients used for instruments.
3. NO EDDY CORRELATION DATA WAS RECORDED FOR rov95604.dat
 

Filename: rov95605.dat
Station: Roving eddy correlation station - met data
Location: Stake 53, Canada Glacier
Date of Establishment: Dec 8, 1995 by Karen Lewis
Author of this report: Karen Lewis
File Period: Dec 13/95 (347) @ 20:30 to Dec 15/95 (349) @ 18:45
Sampling Frequency: every 2 seconds
Averaging and Output Interval: every 15 minutes
Program name: eddy version 1.2
 
* 1. array I.D.
     o1
2. day
     ok
3. time
     ok
4. mean W'
     ok
5. mean T'
     ok
6. mean lnVh'
     ok
7. mean Vh'
     ok
8. standard deviation W
     o1
9. standard deviation T
     o1
10. standard deviation lnVh
     o1
11. standard deviation Vh
     o1
12. sample H
     ok
13. sample LE
     ok
14. Sample
     ok
 
*Notes:
1. Process only arrays with ID# 21
2. Array ID# 12 is EC data; array ID# 11 is startup information
including calibration coefficients used for instruments.
 

Filename: rov95606.dat
Station: Roving eddy correlation station - met data
Location: Stake 50, Canada Glacier
Date of Establishment: Dec 8, 1995 by Karen Lewis
Author of this report: Karen Lewis
File Period: Dec 15/95 (349) @ 20:45 to Dec 16/95 (350) @ 20:00
Sampling Frequency: every 2 seconds
Averaging and Output Interval: every 15 minutes
Program name: eddy version 1.2
 
* 1. array I.D.
     o1
2. day
     ok
3. time
     ok
4. mean W'
     ok
5. mean T'
     ok
6. mean lnVh'
     ok
7. mean Vh'
     ok
8. standard deviation W
     o1
9. standard deviation T
     o1
10. standard deviation lnVh
     o1
11. standard deviation Vh
     o1
12. sample H
     omit first timestep; remaining data ok
13. sample LE
     omit first timestep; remaining data ok
14. Sample
     omit first timestep; remaining data ok
 
*Notes:
1. Process only arrays with ID# 21
2. Array ID# 12 is EC data; array ID# 11 is startup information
including calibration coefficients used for instruments.
 

Filename: rov95607.dat
Station: Roving eddy correlation station - met data
Location: Stake 65, Canada Glacier
Date of Establishment: Dec 8, 1995 by Karen Lewis
Author of this report: Karen Lewis
File Period: Dec 16/95 (350) @ 22:45 to Dec 17/95 (351) @ 16:30
Sampling Frequency: every 2 seconds
Averaging and Output Interval: every 15 minutes
Program name: eddy version 1.2
 
* 1. array I.D.
     o1
2. day
     ok
3. time
     ok
4. mean W'
     ok
5. mean T'
     ok
6. mean lnVh'
     ok
7. mean Vh'
     ok
8. standard deviation W
     o1
9. standard deviation T
     o1
10. standard deviation lnVh
     o1
11. standard deviation Vh
     o1
12. sample H
     ok
13. sample LE
     ok
14. Sample
     ok
 
*Notes:
1. Process only arrays with ID# 21
2. Array ID# 12 is EC data; array ID# 11 is startup information
including calibration coefficients used for instruments.